Category - Water Cooling/Pendingin Air : Sensor
Flow TX Plus
Brand: Thermaltake | SKU: CL-W0138 | Price: Rp.237,500





Easy to position:
 
- The flow meter can be placed anywhere within the liquid cycle.
Accurate monitoring and fast response:
 
- Transparent cover clearly shows the movement of the coolant.
 
- Sensitive probe provides most accurate water temperature
 
- Digital monitor shows water temperature and provides overheating warning alert.
Easy installation:
 
- The quick install connector of flow meter is suitable for tubing of ID9.5mm(3/8�)



 
Detailed information
Clearly shows the movement of the coolant
Quick Install Connector

Application- Install Flow TX Plus with Thermaltake BigWater 735
Flow TX plus
CPU waterblock of Big Water 735
12cm radiator of BigWater 735
Liquid tank of BigWater 735
P400 pump of BigWater 735

There are two temperature shown on the screen (T1, T2).
T1 always mean pre-setting temperature as well as
T2 representatives the temperature from sensor.

ON / OFF: power on or power off switch.
C/F : Celsius and Fahrenheit display switch.
RESET: clean the temperature setting. (MAX & MIN)
REC: Please adjust the pre-setting temperature by using the cross-head screw driver.

Whatever it shows the temperature you would like to set, ( the screen should be shown without MIN or MAX, see fig 1), please press the button "REC" to record the temperature.
NOTE:
When the screen is shown MAX, it means the highest temperature you have recorded. In the meanwhile, T1 is the highest temperature you set, T2 is the highest temperature that the sensor detected.
NOTE:
When the screen is shown MIN, it means the lowest temperature you have recorded. In the meanwhile, T1 is the lowest temperature you set, T2 is the lowest temperature that the sensor detected.
 


Model name
Flow TX Plus
P/N
CL-W0138
Dimension of main body
(H x W x D)
60mm(H) x 35 mm (W) x 25 mm (D)
Quick install Connector
For 9.5mm ID (3/8“) tubing

LCD monitor
Sampling Rate
1 SEC
RANGE
0°C to 90 °C (32°F to 194 °F )
Resolution
0.1 °C (0.1 °F)
Accuracy
+/- 1 °C (+/-2 °F)
Alarm Setting Range
40°C ~ 90°C

Normal Status

Blue Light
Alarm Warning
Red Light
Weight
140g